【BS英國(guó)標(biāo)準(zhǔn)】BSEN858-2-2003Separatorsystemsforlightliquids(e.g.oilandpetrol)—Part2Selectionofnominalsize,installation,operationandmaintenance.doc
《【BS英國(guó)標(biāo)準(zhǔn)】BSEN858-2-2003Separatorsystemsforlightliquids(e.g.oilandpetrol)—Part2Selectionofnominalsize,installation,operationandmaintenance.doc》由會(huì)員分享,可在線閱讀,更多相關(guān)《【BS英國(guó)標(biāo)準(zhǔn)】BSEN858-2-2003Separatorsystemsforlightliquids(e.g.oilandpetrol)—Part2Selectionofnominalsize,installation,operationandmaintenance.doc(25頁(yè)珍藏版)》請(qǐng)?jiān)谘b配圖網(wǎng)上搜索。
1、BRITISH STANDARD BS EN858-2:2003Separator systems for light liquids (e.g. oil and petrol) Part 2: Selection of nominal size, installation, operation and maintenanceThe European Standard EN 858-2:2003 has the status of aBritish StandardICS 13.060.30-,-,- Copyright British Standards InstitutionReprodu
2、ced by IHS under license with BSI - Uncontrolled CopyDocument provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/200406:12:34 MST Questions or comments about this message: please call the DocumentPolicy Group at 303-397-2295.BS EN 858-2:2003National forewordThis British Standard is the offici
3、al English language version ofEN 858-2:2003.The UK participation in its preparation was entrusted to Technical CommitteeB/505, Wastewater engineering, which has the responsibility to:aid enquirers to understand the text;present to the responsible international/European committee any enquiries on the
4、 interpretation, or proposals for change, and keep the UK interests informed;monitor related international and European developments and promulgate them in the UK.A list of organizations represented on this committee can be obtained on request to its secretary.Cross-referencesThe British Standards w
5、hich implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This public
6、ation does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard does not of itself confer immunity from legal obligations.-,-,-This British Standard was published under the authority of the Standards P
7、olicy and Strategy Committee on15 April 2003 BSI 15 April 2003ISBN 0 580 41600 3Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page,pages 2 to 20, an inside back cover and a back cover.The BSI copyright date displayed in this document indicates when the do
8、cument was last issued.Amd. No.DateCommentsAmendments issued since publicationEUROPEAN STANDARD NORME EUROPENNEEUROPISCHE NORMEN 858-2January 2003ICS 13.060.30English version-,-,-Separator systems for light liquids (e.g. oil and petrol) - Part 2: Selection of nominal size, installation, operation an
9、d maintenanceInstallations de sparation de liquides lgers (par exemple hydrocarbures) - Partie 2: Choix des tailles nominales, installation, service et entretienAbscheideranlagen fr Leichtflssigkeiten (z.B. l und Benzin) - Teil 2: Wahl der Nenngre, Einbau, Betrieb und WartungThis European Standard w
10、as approved by CEN on 29 September 2001.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such
11、 national standards may be obtained on application to the Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and
12、notified to the Management Centre has the same status as the official versions.CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, S
13、pain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATION C O M I T EUR O P EN DE NOR M A L I S A TI ON EUR O P I S C H ES KOM I TEE F R NOR M UNG Management Centre: rue de Stassart, 36 B-1050 Brussels 2003 CENAll rights of exploitation in any form and by any means reserved
14、 worldwide for CEN national Members.Ref. No. EN 858-2:2003 EEN 858-2:2003 (E)ContentspageForeword .31Scope .32Normative references .33Terms and definitions.44Determination of type and size of separator systems .44.1General .44.2Components of separator systems, their combination and application.44.2.
15、1General .44.2.2Bypass separators .44.2.3Classes of separators.54.3Sizing of separators.54.3.1General .54.3.2Factors .54.3.3Combined drainage of rainwater and wastewater .64.3.4Wastewater .64.3.5Rainwater flow rate .84.3.6Spillages .84.3.7Quantity of light liquid .84.3.8Special cases.94.4Sludge trap
16、s .95Installation .95.1Limitations .95.2Retention of light liquid .105.3Automatic warning devices and electrical devices .105.4Drainage to and from separator systems .105.5Place of installation .105.6Protection against escape of light liquids.105.7Connection to the drainage system .126Operation, ins
17、pection and maintenance .12Annex A (informative) Density factor fd for particular light liquids and combination of components .14Annex B (informative) Configuration and application of separator systems.17Bibliography .202-,-,-EN 858-2:2003 (E)ForewordThis European Standard (EN 858-2:2003) has been p
18、repared by Technical Committee CEN/TC 165 Wastewater engineering, the secretariat of which is held by DIN.This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2003, and conflicting national standa
19、rds shall be withdrawn at the latest by July 2003.-,-,-It is the second part of a two part standard for separator systems for light liquids. Part 1 gives principles of design, performance and testing, marking and quality control of separator systems for light liquids.When pollution control requires
20、the treatment of pollutants other than light liquids, additional measures can be necessary.The annexes A and B are informative.According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Be
21、lgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta, Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and the United Kingdom.1ScopeThis European Standard applies to separator systems used to separate hydrocarbons of
22、 mineral origin from wastewater. It does not apply to grease and oils of vegetable or animal origin nor to separation of emulsions or solutions.This European Standard provides guidance on the selection of nominal sizes, as well as the installation operation and maintenance of light liquid separators
23、 manufactured in accordance with EN 858-1. It also gives advice on the suitability of cleansing agents if they are discharged to a separator.2Normative referencesThis European Standard incorporates by dated or undated reference, provisions from other publications. These normative references are cite
24、d at the appropriate places in the text, and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references the latest editio
25、n of the publication referred to applies (including amendments).EN 752-2, Drain and sewer systems outside buildings Part 2: Performance requirements.EN 752-4, Drain and sewer systems outside buildings Part 4: Hydraulic design and environmental consideration.EN 858-1:2002, Separator systems for light
26、 liquids (e.g. oil and petrol) Part 1: Principles of design, performance and testing, marking and quality control.3Copyright British Standards InstitutionReproduced by IHS under license with BSI - Uncontrolled CopyDocument provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/200406:12:34 MST Qu
27、estions or comments about this message: please call the DocumentPolicy Group at 303-397-2295.EN 858-2:2003 (E)3Terms and definitionsFor the purposes of this European Standard, the terms and definitions given in EN 858-1 as well as the following term and definition apply.3.1cleansing agentchemical su
28、bstance which, when combined with light liquids, initially forms an emulsion during cleaning process that rapidly breaks down in the separator4Determination of type and size of separator systems4.1GeneralSeparator systems are used in a wide variety of situations to fulfil a number of different requi
29、rements. It is important to establish why a separator system is needed and what specific function it is expected to fulfil before selecting the appropriate size and type of installation.Generally, separator systems are installed for one or more of the following reasons:a)to treat waste water (trade
30、effluent) from industrial processes, vehicle washing, cleansing of oil covered parts or other sources, e.g. petrol station forecourts;b)to treat oil contaminated rainwater (run-off) from impervious areas, e.g. car parks, roads, factory yard areas;c)to retain any spillage of light liquid and to prote
31、ct the surrounding area.Where there is no specific sizing method given by a regulatory authority the following guidance on sizing of the separator system shall be used:4.2Components of separator systems, their combination and application4.2.1GeneralThe component parts of separator systems complying
32、with EN 858-1 are listed in Table 1.Table 1 Components of separator systemsComponentsCode letterSludge trapSSeparator Class IIII, II b (for bypass separators)Separator Class II, I b (for bypass separators)Sampling shaftPAnnex B gives guidance on the selection of components to suit particular applica
33、tions.4.2.2Bypass separatorsBypass separators include a device to allow a flow in excess of the maximum permissible flow to bypass the separator.4-,-,-EN 858-2:2003 (E)Bypass separators are not suitable for category a) uses (see 4.1). They shall be used only in locations where it is unlikely that th
34、ere will be significant hydrocarbon contamination during times of heavy rainfall.Separator systems shall not surcharge or cause surcharging upstream when subject to their maximum design flow.4.2.3Classes of separatorsClasses of separators (class I and II) are defined in EN 858-1:2002, clause 4.Class
35、 I separators provide a higher degree of separation than class II separators (see Table B.2 for applications).4.3Sizing of separators4.3.1GeneralThe sizing of light liquid separators shall be based on the nature and flow rate of the liquids to be treated and will need to take account of: maximum flo
36、w rate of rain water; maximum flow rate of waste water (trade effluent); density of the light liquid; presence of substances that may impede separation (e.g. detergents). The sizing does not take into account special operational conditions (see 4.3.8).The size of the separator shall be calculated fr
37、om the following formula:Copyright British Standards InstitutionReproduced by IHS under license with BSI - Uncontrolled CopyDocument provided by IHS Licensee=Bureau Veritas/5959906001, 11/08/200406:12:34 MST Questions or comments about this message: please call the DocumentPolicy Group at 303-397-22
38、95.NS = (Qr + f x Qs ) f d(1)-,-,-whereNS is the nominal size of the separator;Qr is the maximum flow rate of rainwater, in l/s;Qs is the maximum flow rate of wastewater, in l/s;fdis the density factor for the relevant light liquid;fxis the impediment factor depending on the nature of the discharge.
39、4.3.2Factors4.3.2.1Impediment factor fxThe impediment factor fx allows for unfavourable separating conditions, e.g. where detergents are present in the wastewater. The minimum recommended impediment factors are listed in Table 2.5EN 858-2:2003 (E)Table 2 Minimum impediment factors fxDischarge type i
40、n accordance with 4.1fxa)2b)not relevant as Qs = 0 (only rainwater)c)14.3.2.2Density factor fdThe density factor fd allows for differing densities of light liquids when using different combinations of system components. Additional information is given in annex A.Table 3 Density factors fdDensity g/c
41、mup to 0,85over 0,85 up to 0,90over 0,90 up to 0,95CombinationDensity factor fdS-II-P123S-I-P1 a1,5 a2 aS-II-I-P1 b1 b1 ba For class I separators operating by gravity only, use fd for class II separator.b For class I and class II separators.4.3.2.3Cleansing agents-,-,-Cleansing agent manufacturers s
42、hall submit a declaration stating that the product is free from organically combined halogen compounds or BTX aromas. Only cleansing agents which form temporary stable emulsions with light liquids and then de-emulsify after the cleaning process should be used. Instructions for use shall also be prov
43、ided, together with the effects of mixing with other cleansing agents, particularly regarding the separation process.4.3.3Combined drainage of rainwater and wastewaterIf a separator is receiving rainwater and wastewater, e.g. from vehicle washing, and the two maximum flows are not expected to occur
44、simultaneously, then the separator can be sized for the higher flow rate.4.3.4WastewaterThe wastewater inflow in accordance with 4.1, case a), shall be calculated as the sum of the contributing flows from the following formula:Qs = Qs1 + Qs 2 + Qs3 + .(2)whereQs1 is the flow from draw-off points, in
45、 l/s;Qs2 is the flow from car washes, in l/s;6EN 858-2:2003 (E)Qs3 is the flow from high pressure cleaning units, in l/s. Any other contributing flow shall be added.4.3.4.1Draw-off pointsWhere it is not possible to determine the maximum flow from draw-off points by measurement, it may be estimated b
46、y using Table 4. Table 4 takes account the probability of the likelihood of all draw-off points, irrespective of size, being used at the same time. Calculations should be based on the flow rates from the largest draw-off points first.Table 4 Flow rates from draw-off pointsDraw-off pointsNominal diam
47、eterFlows from draw-off point Qs1 a in l/s1st point2nd point3rd point4th point5th point and subsequentDN 150,50,50,350,250,1DN 201,01,00,700,500,2DN 251,71,71,200,850,3aValues given for supply pressure of about 4 bar to 5 bar; other supply pressures may cause differentQv-values.Example for calculation of Qs1 for 1 DN 15, 1 DN 20 and 2 DN 25 points:1st point DN 25 = 1,7 l/s;2nd point DN 25 = 1,7 l/s;3rd point DN 20 = 0,7 l/s;4th point DN 15 = 0,25 l/s;Qs
- 溫馨提示:
1: 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
2: 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶(hù)所有。
3.本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒(méi)有圖紙預(yù)覽就沒(méi)有圖紙。
4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
5. 裝配圖網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶(hù)上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶(hù)上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶(hù)因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。
最新文檔
- 6.煤礦安全生產(chǎn)科普知識(shí)競(jìng)賽題含答案
- 2.煤礦爆破工技能鑒定試題含答案
- 3.爆破工培訓(xùn)考試試題含答案
- 2.煤礦安全監(jiān)察人員模擬考試題庫(kù)試卷含答案
- 3.金屬非金屬礦山安全管理人員(地下礦山)安全生產(chǎn)模擬考試題庫(kù)試卷含答案
- 4.煤礦特種作業(yè)人員井下電鉗工模擬考試題庫(kù)試卷含答案
- 1 煤礦安全生產(chǎn)及管理知識(shí)測(cè)試題庫(kù)及答案
- 2 各種煤礦安全考試試題含答案
- 1 煤礦安全檢查考試題
- 1 井下放炮員練習(xí)題含答案
- 2煤礦安全監(jiān)測(cè)工種技術(shù)比武題庫(kù)含解析
- 1 礦山應(yīng)急救援安全知識(shí)競(jìng)賽試題
- 1 礦井泵工考試練習(xí)題含答案
- 2煤礦爆破工考試復(fù)習(xí)題含答案
- 1 各種煤礦安全考試試題含答案