1、.英文資料The contral techniques drives and contrals handbookChapter A4Torque, speed and position controlA4.1General principlesA4.1.1The ideal control systemMany applications exist where something has to be controlled to follow a reference quantity. For example, the speed of a large motor may be set from

2、 a low-power control signal. This can be achieved using a variable-speed drive as described in the following.Ideally, the relationship between the reference and the motor speed should be linear, and the speed should change instantly with changes in the reference. Any control system can be represente

3、d as in Figure A4.1b, with an input reference signal, a transfer function F and an output. For the system to be ideal, the transfer function F would be a simple constant, so that the output would be proportional to the reference with no delay.Figure A4.1Variable-speed drive and motorA4.1.2Open-loop

4、controlUnfortunately, the transfer function of many practical systems is not a constant, and so without any form of feedback from the output to correct for the non-ideal nature of the transfer function, the output does not follow the demand as required. Using an induction motor supplied bya simple o

5、pen-loop variable-speed drive as an example, the following illustrates some unwanted effects that can occur in practical systems:Speed regulation. The output of a simple open-loop drive is a fixed frequency that is proportional to the speed reference, and so the frequency applied to the motor remain

6、s constant for a constant speed reference. The speed of the motor drops as load is applied because of the slip characteristic of the motor, and so the speed does not remain at the required level.Instability. It is possible under certain load conditions and at certain frequencies for the motor speed

7、to oscillate around the required speed, even though the applied frequency is constant. Another major source of instability in.rotating mechanical systems is low-loss elastic couplings and shafts. Non-linearity. There are many possible sources of non-linearity. If, forexample, the motor is connected

8、to a gearbox, the speed at the output of the gearbox could be affected by backlash between the gears.Variations with temperature. Some aspects of the system transfer function may vary with temperature. For example, the slip of an induction motor increases as the motor heats up, and so for a given lo

9、ad the motor speed may reduce from the starting speed when the motor was cold.Delay. With a simple open-loop inverter and induction motor there can be a delay before the motor speed reaches the demanded level after a change in the speed reference. In very simple applications such as controlling the

10、speed of a conveyor belt, this type of delay may not be a problem. In more complex systems, such as on a machine tool axis, delays have a significant effect on the quality of the system.These are just some of the unwanted effects that can be produced if an open-loop control system is used. One metho

11、d that improves the quality of the controller is to use a measure of the output quantity to apply some feedback to give closed-loop control.A4.1.3Closed-loop controlThe simple open-loop drive of Section A4.1.2 can be replaced with a control system as in Figure A4.2. This control system not only prov

12、ides a means to correct for any error in the output variable, but also enable a stable response characteristic A4.2 Controllers in a driveA4.2.1GeneralAlthough a modern variable-speed drive includes many features, the basic function of the drive is to control torque (or force), speed or position. Be

13、fore proceeding to the specific details of how different types of variable-speed drive function, the theory of control for each of these quantities is discussed. A position control system is shown in Figure A4.5. This includes an inner speed controller, and within the speed controller there is an in

14、ner torque controller. It is possible to create a system where the position controller determines the mechanical torque that is applied to the load directly without the inner speed and torque loops. However, the position controller would need to be able to control the complex2combined transfer funct

15、ion of the motor windings, the mechanical load and the conversion from speed to position.Therefore it is more usual to use the format shown in Figure A4.5. The other advantage of this approach is that limits can be applied to the range or rate of change of speed and torque between each of the contro

16、llers. When a system is required to control speed only, the position controller is omitted, and when a system is required to control torque only, the position and speed controllers are omitted.A position sensor is shown providing feedback for the system, but this may be replaced by a speed sensor or

17、 it may be omitted altogether as follows. Position information is required by the torque controller to function in an a.c. motor drive (see the dotted line). If position feedback is provided the speed feed-back is derived as the change of speed over a fixed sample period. Sensorless schemes are poss

18、ible for speed and torque control of a.c. motors, in which case the sensor is not required.Position feedback is not necessaryfor the torque controller in a d.c. motor drive, so a speed feedback device such as a tacho-generator can be used to provide the feed-back for the speed controller. Again, sen

19、sorless schemes are possible where a speed feedback device is not required.A4.2.2Torque controlA torque controller for a rotary motor, or a force controller for a linear motor, is the basic inner loop of most variable-speed drives. Only torque control is discussed here, but the principles also apply

20、 to force control for a linear application. In order to explain the principles of torque control, the simple d.c. motor system in Figure A4.6 is used as an example. The analysis of torque control in an a.c. motor can be done in exactly the same way, provided suitable transformations are carried out

21、in the drive. These transformations will be discussed later.The torque demand or reference (Te*) is converted by the torque controller into a current in the motor armature, and the motor itself converts the current into torqueFigure A4.6 Torque and current controllers in a d.c. motor drive: (a) torq

22、ue control;3(b) current controlto drive the mechanical load. Figure A4.6b shows the systemrequired to convert the torque reference into motor current. The torque reference(Te*) is first transformed into a current reference (ia*) by including the scalingeffect of the motor flux. The motor flux, contr

23、olled by the motor field current (if ),is normally reduced from its rated level at higher speeds when the terminal voltagewould exceed the maximum possible output voltage of the power circuit withoutthis adjustment. Current limits are then applied to the current reference so that therequired current

24、 does not exceed the capa-bilities of the drive. The currentreference (limited to a maximum level) becomes the input for the PI controller.The electrical equivalent circuit of the motor consists of a resistance (Ra), aninductance (La) and a back emf that is proportional to flux and speed(Kevc/crated

25、).The PI controller alone could successfully control the current in this circuit because as the speed increases, the voltage required to overcome the back emf would be pro-vided by the integral term. The integral control is likely to be relatively slow, so to improve the performance during transient

26、 speed changes a voltage feed-forward term equivalent to Kevc/crated is included. The combined output of the PI controller and the voltage feed-forward term form the voltage reference (va*), and in response to this the power circuit applies a voltage (va) to the motor s electrical circuit to give a

27、current (ia). The current is measured by a sensor and used as feedback for the current controller.As well as the linear components shown in Figure A4.6, the current control loop in a digital drive includes sample delays as well as delays caused by the power circuit. In practice, the response of the

28、controller is dominated by the proportional gain. In particular, if a voltage feed-forward term is used, the integral term has very little effect on the transient response.Setting of the control loop gains is clearly very important in optimising the per-formance of the control loop. One of the simpl

29、est methods to determine a suitable proportional gain is to use the following equation:where La is the motor inductance and Ts the current controller sample time. K is a con-stant that is related to the current and voltage scaling, and the delays present in the control system and power circuit. Most

30、 modern variable-speed drives include auto-tuning algorithms based on measurement of the electrical parameters of the4motor taken by the drive itself, and so the user does not normally need to adjust the current controller gains.It is useful to know the closed-loop transfer function of the torque co

31、ntroller (i.e. Te/Te*) so that the response of a stand-alone torque controller, or the effect of an inner torque controller on outer loops such as a speed controller, can be predicted. As the response is dominated by the system delays it is appropriate to represent the closed-loop response as simple

32、 gains and a unity gain transport delay as shown in Figure A4.7.The torque reference could be in N m, but it is more conventional to use a value that is a percentage of the rated motor torque. Figure A4.7a gives the transfer function when the torque controller is used alone. Kt is the torque constan

33、t of the motor in N m A21. If the torque controller is used with an outer speed controller a slightly different representation must be used, as in Figure A4.7b. The speed controller pro-duces a torque reference where a value of unity corresponds to a current level that is specified for the size or r

34、ating of the drive. From a control perspective it is unimportant whether this is the maximum current capability of the drive, the rated current or some other level. The actual levelused is defined as Kc (in amperes), and should be included in the transfer function as shown. These simple models allow

35、 the drive user to predict the performance of a stand-alone torque controller or a torque controller with an outer speed loop.A4.2.3Flux controlThe motor flux and hence the motorterminal voltage for a given speed are defined by the flux producing current. In the example of a simple d.c. motor drive

36、used pre-viously, the motor flux level is set by the field current, if. The flux controller (Figure A4.8) includes an inner current loop and an outer loop that maintains rated flux in the motor until the armature terminal voltage reaches its maximum limit. When the motor speed increases above rated

37、speed it then controls the field current and hence the flux, so that the armature voltage remains at the maximum required level.A4.2.4Speed controlA4.2.4.1Basic speed control5Closed-loop speed control can be achieved by applying a simple PI controller around the torque controller described previousl

38、y. For the purposes of this analysis it is assumed that the load is an inertia J, with a torque Td that is not related to speed (friction is neglected). The resulting system is shown in Figure A4.10 Figure A4.10 Speed controllerIf the PI controller is represented as Kp t Ki/s, the torque controller

39、is assumed to be ideal with no delays so that the unity transport delay can be neglected, and the inertia load is represented as 1/Js then the forward loop gain in the s domain is given byThe closed-loop transfer function in the s domain v(s)/v*(s) is given by G(s)/ 1 t G(s). Substituting for G(s) a

40、nd rearranging givesIf the natural frequency of the system is defined as vn ? (KcKtKi=J ) and the damping factor is defined as j ? vnKp/(2Ki) thenAs with the torque controller, it is useful to know the closed-loop response so that the response of a stand-alone speed controller, or the effect of an i

41、nner speed controller on an outer position loop, can be predicted. If a moderate response is required from the speed controller it is not significantly affected by system delays, and a linear transfer function such as equation (A4.4) can be used. All the constants in these equations and the delays a

42、ssociated with the current controllers are normally provided to users so that calculations and/or simulations can be carried out to predict the performance of the speed controller.In addition to providing the required closed-loop step response, it is important for the system to be able to prevent un

43、wanted movement as the result of an applied torque transient. This could be because a load is suddenly applied or because of an uneven load. The ability to prevent unwanted movement is referred to as stiffness. The com-pliance angle of the system is a measure ofFigure A4.11 Responses of an ideal spe

44、ed controller: (a) closed-loop step response;Figure A4.12Unwanted delays in a practical digital driveDynamics 115UMC 3 000 rpm servo motor (Kt ? 1.6 N m A21, J ? 0.00078 kg m2) with the speed controller gains set to Kp ? 0.0693j and Ki ? 14.32.As the damping factor is increased, the closed-loop resp

45、onse overshoot is reduced and the speed of response improves. The closed-loop response includes 106per cent overshoot with a damping factor of unity because of the s term in its numerator.As the damping factor is increased, the overshoot of the response to a torque tran-sient is reduced and the resp

46、onse becomes slower.In this case there is no s term in the numerator and the response includes no overshoot with a damping factor of unity.It would appear from these results that the higher the proportional gain, and hence the higher the damping factor the better the responses; however, the results

47、so far assume an ideal torque controller and no additional unwanted delays. In a real digital drive system the delays given in Figure A4.12 are likely to be present. A delay is included to represent the sample period for speed measurement, but this is only relevant if the speed feedback is derived f

48、rom a position feedback device such as an encoder and is measured as a change of position over a fixed sample period.The effect of the unwanted delays can be seen in the closed-loop step response for a real system as shown in Figure A4.13. In each case the response of the real system has more oversh

49、oot than the ideal system. If the damping factor is set to unity then the overshoot may be acceptable, but with a damping factor of1.25 the response is quite oscillatory and is likely to be unacceptable. The effect of the unwanted delays is more pronounced the longer the delay and also as the set ba

50、ndwidth of the speed controller is increased.The effect of the additional delays can be seen in the Bode plot of the closed-loop response of the speed controller set up to give unity damping factor (Figure A4.14). The frequency at the 23 dB point of the gain characteristic has increased significantl

51、y from the ideal speed controller, whereas the frequency at the 608 point of the phase characteristic is almost unchanged. If this is to be used as a stand-alone controller the gain characteristic could be used to predict the bandwidth, although it should be noted that the gain is greater than unity

52、 at some frequencies. Often the bandwidth based on the gain characteristic is the only bandwidth that is quoted, because this makes the performance appear to be better, in this case 2 000 rad s21.Figure A4.13Effect of delays on a closed-loop step response:(a) damping factor ? 1; (b) damping factor ?

53、 1.25 based on the phase delay7(672 rad s21 for this example) must be used, as this affects the performance of the outer loop.Unwanted delays limit the performance of the speed controller. The quantised nature of speed feedback when it is derived from a position sensor as the change of position over

54、 a fixed sample period can also limit this. A high proportional gain in the speed controller, and hence high bandwidth, generate high-frequency torque ripple and acoustic noise from the quantised speed feedback.Figure A4.14Bode plot of closed-loop response of a speed controllerThe characteristic def

55、ined by equation (4.11) is shown in Figure A4.15. The required damping factor must first be selected, and from this the ratio vbw/vn is taken from the graph. For example, if a damping factor of unity is required, the value of vbw/vn is 2.5.Figure A4.15Effect of damping factor on bandwidthThe definit

56、ion of damping factor is j ? vnKp/(2Ki). By rearranging this and substitut-ing for natural frequency, a suitable value for the proportional gain can be derived:Selection based on compliance angleFrom equation (A4.9) the steady-state response to a torque transient can be derived by setting s ? 0. The

57、 resulting change of output angle for a given steady-state torque Td isIf the compliance angle is defined as the change of output angle with a steady-statetorque equal to KcKt (i.e. the torque produced by the motor with a torque producing current equal to Kc) then a suitable value of integral gain c

58、an be selected for a given compliance angle uc asThe proportional gain can then be determined in the same way as for the selection based on bandwidth using equation (A4.14).If the load (including motor) inertia is known, or it is possible for the drive to measure the load inertia using an auto-tunin

59、g algorithm, then the user need only enter the required damping factor and the speed loop bandwidth or compliance angle into the drive parameters. The drive can then automatically set suitable values for the speed controller gains.A4.2.4.3Speed control with torque feed-forwardThere are situations wh

60、ere it is desirable to have low-speed controller gains,8for example in a winder application where the inertia of the load may change in time,Figure A4.16Speed controller with torque feed-forwardor an elevator where high gains would excite resonances in the system, making it unstable. The disadvantag

61、e of using low gains is that the response of the speed con-troller is degraded. If the load torque characteristic is known, it is possible to use a torque feed-forward term to significantly improve the response and still use low-speed controller gains. Figure A4.16 shows a system with a known inerti

62、a load using torque feed-forward.The profile generator produces the required speed reference v*, which may be a simple linear ramp that accelerates and decelerates the load. It also produces the rate of change of speed or acceleration sv* (dv*/dt in the time domain). When this is scaled to include t

63、he inertia and the system constants, it gives a current reference that should accelerate and decelerate the load as required. Now the speed controller is only required as a trim to compensate for inaccuracies in the torque feed-forward. The response of the system is only limited by the response of t

64、he current controllers and the sample rate of the profile generator, and not by the response of the speed controller.A4.2.5Position controlA4.2.5.1Basic position controlIf position control is required, an additional outer loop is applied to the speed control-ler as shown in Figure A4.17. The position control loop only includes a proportional term Kv. An integral term is not generally required as any static error gives a speed reference v*, and the integral term in the speed controller forces the load to move until the position error

展開閱讀全文
溫馨提示:
1: 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
2: 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權益歸上傳用戶所有。
3.本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
4. 未經權益所有人同意不得將文件中的內容挪作商業(yè)或盈利用途。
5. 裝配圖網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
6. 下載文件中如有侵權或不適當內容,請與我們聯(lián)系,我們立即糾正。
7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

相關資源

更多
正為您匹配相似的精品文檔
關于我們 - 網站聲明 - 網站地圖 - 資源地圖 - 友情鏈接 - 網站客服 - 聯(lián)系我們

copyright@ 2023-2025  zhuangpeitu.com 裝配圖網版權所有   聯(lián)系電話:18123376007

備案號:ICP2024067431-1 川公網安備51140202000466號


本站為文檔C2C交易模式,即用戶上傳的文檔直接被用戶下載,本站只是中間服務平臺,本站所有文檔下載所得的收益歸上傳人(含作者)所有。裝配圖網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對上載內容本身不做任何修改或編輯。若文檔所含內容侵犯了您的版權或隱私,請立即通知裝配圖網,我們立即給予刪除!